RULER®

We innovate with purpose to increase the uptime of your equipment by keeping the oil clean, extending it's life and inherently positively impacting the environment.

Why use RULER?

With enhanced processing, higher resolution, RULER® V™ provides critical information on the health of your lubricant. Discover oxidation earlier than with any other technologies. The RULER V provides the full picture of a fluid’s antioxidant health – it’s a window into the health of your lubricant. This technology is a critical part of an effective condition monitoring program.

In the past, indirect measurements of the fluid’s antioxidants were taken. Tests such as RPVOT (ASTM D2272) measure the oxidative stability of the fluid inferring antioxidant levels. This technology has been shown to be less effective in today’s complex formulations employing hydro-treated mineral oils and new antioxidant technologies.

Other techniques to directly measure antioxidants such as infrared analysis (FTIR) often cannot provide the full picture. FTIR interpretation is complex and some additive components mask the critical antioxidant region.

Field Tested. Industry Supported.

Be comfortable that your RULER V investment is supported by industry, the RULER technology has received strong industry support over the last 15 years. There are four ASTM standards written around it (D7590, D6971, D6810 and D7527) as well as industry guidelines (DASTM4378 D6224 and DIN – VGB M416). Major equipment OEMs such as Siemens and GE recommend RULER as part of a condition monitoring program. Furthermore, most oil and additive manufacturers use the RULER technology as both a condition monitoring and research tool to gain further insights into their lubricant formulations.

Contact us for additional product information.

The RULER V has a Brilliant 7″ display works in full sunlight and comes with an assortment of value-enhancing features such as:

  • a microphone that allows you to dictate relevant sample data rather than having to type it in,
  • a built-in 8-megapixel camera that can take a picture of your MPC patch (Membrane Patch Colorimetry, ASTM D7843) for measuring varnish potential,
  • and a built-in report template that provides space for integration of the MPC patch picture and comments.

All of this elegance and durability, yet it weighs less than 1.5lbs (0.7kg)

Recent Case Studies

Mobil™ Solvancer® helps paper mill minimize equipment downtime and ensure equipment availability

Mobil™ Solvancer® helps paper mill minimize equipment downtime and ensure equipment availability

Overview A South Carolina paper packaging mill was facing degraded oil and increasing varnish and oxidation in their paper machine system. The Mobil™ engineering team ran a Maximum …


Manufacturing Mobil Solvancer North America Pulp & Paper USA
Mobil DTE™ and Mobil Solvancer® assist nuclear facility in varnish prevention and extended oil life

Mobil DTE™ and Mobil Solvancer® assist nuclear facility in varnish prevention and extended oil life

Overview A Minnesota nuclear power facility was able to extend the life of their turbine lubricant and avoid a costly 2025 outage by partnering with the Mobil™ Engineering …


Energy Mobil Solvancer North America USA
Keeping Food Production Lines Running in Bolivia with DECON

Keeping Food Production Lines Running in Bolivia with DECON

Overview Avícola Sofía Ltda, a major food processing facility in Bolivia, experienced rising temperatures, darkening oil, and shortened oil drain intervals on two Atlas Copco compressors. These issues …


Bolivia DECON Food & Beverage LATAM